Thermis Smart heating and thermal insight for UK spaces.

Thermis

Smart heating and thermal insight for UK spaces.

Latest Articles

Loop by Loop: A Cold-Start Thermal Check for Wet Underfloor Heating
Thermal Imaging

Loop by Loop: A Cold-Start Thermal Check for Wet Underfloor Heating

A wet underfloor heating system rarely announces an imbalance. It reveals one slowly, loop by loop, as the screed warms after a cold start. This guide explains how a thermal camera sequence, read alongside manifold flow rates and actuator behaviour, can turn a vague sense of uneven warmth into usable evidence.

The Ceiling's Weak Point: A Thermal Audit of the Loft Hatch
Thermal Imaging

The Ceiling's Weak Point: A Thermal Audit of the Loft Hatch

A loft hatch is a small opening with a disproportionate role in winter heat loss. This thermal audit explains how to test the hatch, frame and ladder gap with a camera and smoke pen, then verify the improvement after sealing and insulating.

The First Hour Is Evidence: Diagnosing How a UK Home Warms from Cold
Smart Heating

The First Hour Is Evidence: Diagnosing How a UK Home Warms from Cold

The first hour of a heating cycle is more than a comfort interval; it is a diagnostic record of how a home, its emitters and its boiler behave together. This guide explains how to read smart thermostat logs, room-by-room traces and thermal images to separate slow thermal mass from undersized radiators, trapped air, poor balancing and boiler cycling.

Compressor Heat in the Winter Kitchen: Auditing Appliance Rejection Before the Cold Snap
Thermal Imaging

Compressor Heat in the Winter Kitchen: Auditing Appliance Rejection Before the Cold Snap

Fridges, freezers and undercounter appliances quietly reject heat into UK kitchens, yet smart heating schedules rarely account for it. This audit uses thermal imaging and simple logging to separate useful appliance warmth from wasted compressor effort before the 2026–27 winter.

Steam, Sensors and Stolen Warmth: A Bathroom Ventilation Audit for UK Homes
Smart Heating

Steam, Sensors and Stolen Warmth: A Bathroom Ventilation Audit for UK Homes

Bathroom extractor fans are often treated as condensation fixtures rather than part of the heating envelope. This audit explains how overrun timers, trickle vents and humidity sensors can become uncontrolled heat-loss routes, and how thermal imaging and simple pressure checks can reveal the problem before a thermostat is changed.

The Eighteen-Degree Evidence Standard: Auditing Winter Warmth at Bed Height
Smart Heating

The Eighteen-Degree Evidence Standard: Auditing Winter Warmth at Bed Height

Cold-health alerts for winter 2026 make the 18°C benchmark visible again, but a thermostat in the hall cannot prove a bedroom is warm where a person sleeps. This audit sets out how to use existing smart sensors, overnight logs and simple surface checks to verify warmth at occupant height before buying more equipment.

Cold Floors, Warm Desks: A Thermal Audit for the Garden Studio
Thermal Imaging

Cold Floors, Warm Desks: A Thermal Audit for the Garden Studio

By mid-November, a garden office stops behaving like a spare room and starts behaving like a small detached building with its own weather. This practical thermal-camera walkthrough shows UK homeowners how to find the real weak points — floor bridging, single-glazed cold spots and hidden air paths — before buying another heater.

When the Outdoor Coil Blooms White: A Thermal Camera Guide to Heat Pump Defrost Cycles
Thermal Imaging

When the Outdoor Coil Blooms White: A Thermal Camera Guide to Heat Pump Defrost Cycles

Frost on a heat pump’s outdoor coil is not automatically a fault; it is part of the working cycle. This guide explains how to use a thermal camera to distinguish normal defrost behaviour from a system that is struggling, and what evidence to record before calling an installer.

Front Door Bias: Why a Hallway Sensor Never Tells the Whole Story
Smart Heating

Front Door Bias: Why a Hallway Sensor Never Tells the Whole Story

The hallway is the default home for British thermostats, yet it is often the least representative room in the house. This investigation uses thermal-camera evidence and a simple relocation test to show how draughts, door cycles and stratification distort every heating decision — and what to do about it.

Foil, Gap, Wall: What a Thermal Camera Reveals About Radiator Reflectors
Thermal Imaging

Foil, Gap, Wall: What a Thermal Camera Reveals About Radiator Reflectors

Radiator reflector panels promise to push heat back into the room, but a thermal camera can reveal what they actually change. This practical UK investigation explains the physics, the fair-test method and the wall types where foil-backed panels are worth considering.

The Meter Is a Witness, Not a Verdict: Half-Hourly Data in a UK Heating Investigation
Smart Heating

The Meter Is a Witness, Not a Verdict: Half-Hourly Data in a UK Heating Investigation

Half-hourly smart meter data can show when a heating system draws power, but it cannot show where heat is lost or how comfort is distributed. This guide separates the useful signal from the misleading artefact and pairs meter patterns with simple thermal checks for UK homes.

The Empty-Room Assumption: Testing Geofenced Heating Against Thermal Mass
Smart Heating

The Empty-Room Assumption: Testing Geofenced Heating Against Thermal Mass

Geofencing is often presented as an automatic saving, but location alone cannot tell a smart thermostat how a building stores heat. This diagnostic plan uses thermostat history, occupancy records and outdoor temperature to decide whether away mode should switch off, set back or stay out of the way.

The Cold Crown of a Radiator: A Thermal Diagnosis Before the Bleed Key
Thermal Imaging

The Cold Crown of a Radiator: A Thermal Diagnosis Before the Bleed Key

A radiator that is warm at the bottom and cool at the top is often assumed to need bleeding, but thermal images can show a different story. This guide explains how UK homeowners can read surface-temperature patterns safely, distinguish air from sludge, balancing and pump issues, and judge when an engineer should take over.

The Room That Reads Warm: Measuring Radiant Comfort Beyond the Thermostat
Smart Heating

The Room That Reads Warm: Measuring Radiant Comfort Beyond the Thermostat

A smart thermostat can report 21°C while occupants still reach for a blanket. This guide explains mean radiant and operative temperature in practical terms, shows how thermal-camera surface readings can be paired with air data, and outlines a low-cost globe thermometer for UK homes.

Before You Call the Glazier: A Dew-Point Diagnosis for Misty Windows
Thermal Imaging

Before You Call the Glazier: A Dew-Point Diagnosis for Misty Windows

Condensation on internal glass is often treated as proof that replacement glazing is overdue. A simple dew-point test, using a hygrometer and a surface thermometer, can separate humidity problems from cold bridging and failed seals before any money is committed.

Reading the Stack: A November Thermal Survey of the Victorian Chimney Breast
Thermal Imaging

Reading the Stack: A November Thermal Survey of the Victorian Chimney Breast

A disused flue is rarely inert. On a cold November evening, the chimney breast can behave as a permanent extract route for warmed air, and thermal imaging makes that path visible before the meter does. This guide sets out how to survey the stack from inside and out, measure the effect of a proper draught excluder, and recognise the point at which efficiency work must stop and Gas Safe work begins.

The Heating Log Is the First Diagnostic Tool: Reading Six Months of Smart Thermostat Data
Smart Heating

The Heating Log Is the First Diagnostic Tool: Reading Six Months of Smart Thermostat Data

Before buying another smart TRV or boiler controller, UK homeowners can learn a great deal from the heating data already sitting in their app. This guide explains how to export six months of setpoint, cycling and room-by-room call-for-heat records, compare them with local degree days, and spot schedule drift, short cycling and occupancy mismatch.

A Fair Frame: Building Deposit-Safe Thermal Evidence for UK Rented Homes
Thermal Imaging

A Fair Frame: Building Deposit-Safe Thermal Evidence for UK Rented Homes

Thermal images can support a damp or cold complaint in a rented home, but only if they are repeatable, contextualised and fairly presented. This protocol sets out camera settings, reference shots, timestamps, moisture readings, privacy handling and a defensible written summary for tenants and landlords.

The Boiler Setting Hiding in Plain Sight: A Practical Check for Weather Compensation
Smart Heating

The Boiler Setting Hiding in Plain Sight: A Practical Check for Weather Compensation

Weather compensation is often available on UK boilers but left disabled or poorly set. This guide explains what it does and how homeowners can verify flow and return temperatures with a thermal camera and a short data log.

Deck the Halls, Not the Cold Spots: A Thermal Audit of Christmas Decor
Thermal Imaging

Deck the Halls, Not the Cold Spots: A Thermal Audit of Christmas Decor

A seasonal UK experiment with a thermal camera and simple temperature sensors shows how trees, cards, curtains and furniture change radiator output and heat distribution. The results are part diagnostics, part decorating guide.